-Is the NMEA2000 connector properly fitted to the unit?
-Do you have power on the NMEA2000 backbone?
-Is the NMEA2000 backbone is properly terminated?
Connect 50 now available for 24V installations!
#beatyesterday #creativityunbound
EmpirBus Studio software have finally been put to rest – thank you for all your great efforts over these years!
Welcome, EmpirBus Logix!!
A new era begins!!
#beatyesterday #creativityunbound
Live previewpc interface via usb mini socket | connect & configure |
integrated gsm module | connectivity wherever |
ip65 protection | durability |
automatic override control | robustness |
interface via usb socket | configure |
integrated wifi module | connectivity |
ip65 protection | durability |
NMEA 2000 | simplicity |
12 x 2 programmable switches | flexibility |
portrait and landscape model | designed to blend in |
led running and alarm indication for each switch | for every need |
user designed switch legends | design your own buttons |
backlight with automatic adjustment | night time operation |
integrated can-bus terminator | simplified |
integrated buzzer | operator feedback and alarm |
EmpirBus SP8 is a 8 way digital switch component for the EmpirBus control, monitoring and distribution system. SP8 is used to provide control inputs to the system via the switches and status information back to the user by the individual LED indicators. Available as vertical (portrait) or horizontal (landspace). Fitting the unit is simple using the supplied template and it may be fitted to any flat surface up to 20mm deep. The SP8 may be fitted internally or externally, when fitted externally the SP8 is waterproof from the front, is UV stable and operates from -20 to +70 deg C.
CAN bus switch panel | via Connect 50 |
8 programmable switches | flexibility |
led, running and alarm indication | dynamic (fixed led colors: orange, orange, red) |
user designed switches | customized symbol or text |
backlight | night time operation |
designed for marine environment | durability & robustness IP67 |
uv stable | designed for outdoor mounting |
Garmin OneHelm connects all of the power and convenience of advanced home automation from your EmpirBus system to the Garmin MFD. It allows you to control onboard electrical and electronic systems like lighting, air-conditioning, navigation lights, wipers, horns, entertainment systems, security systems and much more from your network-connected multifunction display, smartphone or tablet.
EmpirBus is fully integrated with Garmin OneHelm and is the link between the screen and controlling your electrical system.
-Is the NMEA2000 connector properly fitted to the unit?
-Do you have power on the NMEA2000 backbone?
-Is the NMEA2000 backbone is properly terminated?
Unit does not have any connection with the network, check the NMEA2000 network.
-Check network power.
-Check NMEA2000 termination. The network shall have two terminators installed. To be certain you can power OFF the system and measure OHM between pin 4 and 5 (standard Micro C connector). A proper terminated network has 60 Ohm (two 120 Ohm terminator in parallell).
Check ‘Code explanation DCM & MCU’ documentation for more information.
Code explanation DCM & MCU
A system with only DCM modules only one can be master, the unit that switches between ID number and CUA is programmed as master.
If you have an MCU in the system, that one is naturally master in the system.
A rare case can occur if you have replaced a DCM with another DCM unit that previously has been programmed as master. The unit will stay acting as a master even if re-programmed.
This can be seen this when the units are power-cycled, the unit still acting as master takes longer time to power up. To remove master mode from a unit you need the program it with an empty configuration file.
The polarity on the power cables are shifted (plus/minus).
This means that the units doesn’t recognize a master
Check that the NMEA2000 network is properly terminated/connected and powered.
If the option is greyed out there is a master unit missing in the configuration file. Update configuration.
Check that all the units have the latest firmware by performing a firmware upgrade.
If the system has firmware that has not been updated for a long time there might be a need for several retries before the firmware upgrade is successful.
If you have an MCU in the system -start upgrading that units first. Select the master unit separately and perform the upgrade.
The units are still in bootloader mode during a cancelled or failed upgrade of firmware.
Try to upgrade the unit again through Empirbus studio.
-Check connections and that the resistors are attached and OK.
-Check that the correct type of resistors are attached: 68 ohm if its a multi-switch and 120 ohm if it’s a dual fixed multi-switch.
-Check the input channel that the LED turns green when the button in pressed.
Note: only pulse breakers will work with a multi-switch input channel.
-If it’s a new config please check that you have the correct fuse setting on the channel.
-The unit attached to the output channel consumes to much power/current.
-Check that all units have power and COM led flashes green.
-Upgrade MCU to latest firmware, followed by the rest of the units in the system.
-Access P10 on your MCU: Hold ‘enter’ for approx. 10 sec until P10 appears (a beep sound shall be heard during the whole process). Release and press enter one time.
-Copying is done in the P10 menu of the MCU. Copy function 1 (CF1) copies from DCM to MCU and copy function 2 (CF2) from MCU to DCM. Number 2 is to be used in this case as you’d like to copy from MCU to DCM.
-Verify that the MCU (and/or DCM) doesn’t say ‘EoA’ before copying as this indicates that there is an existing conflict of stored switches and a decision has to be made what set of switches to use.
-Press and hold button 7 for about 20 seconds whilst applying power
-Press button 8 three times, now a number will be displayed instead also flashing, this is the base address.
-Use the button 5 and 6 to step down and up the base address.
-When the new base address have been set press and hold button 7 again for about 20 seconds to store.
-The way the base address is displayed on the membrane panel is as follows:
Indication on button 1 is 0 or 1, 0 when off and 1 when lit.
Indication on button 2 is 0 or 2, 0 when off and 2 when lit.
Indication on button 3 is 0 or 4, 0 when off and 4 when lit.
Indication on button 4 is 0 or 8, 0 when off and 8 when lit.
Indication on button 5 is 0 or 16, 0 when off and 16 when lit.
Indication on button 6 is 0 or 32, 0 when off and 32 when lit.
Indication on button 7 is 0 or 64, 0 when off and 64 when lit.
Indication on button 8 is 0 or 128, 0 when off and 128 when lit.
The base address will be the sum of the indicators lit up.
For Example, if Indication on Button 1 + Button 3 => Address is 1+4 = 5.
-Check that all units have the latest firmware installed. Firmware NXT
-Verify that you have not programmed a channel with functions that it doesn’t support:
Fuse settings, channel support on your unit (example: an input channel has been programmed as an output channel), specific channel support under it’s properties.
-Check that the system doesn’t have two masters.
The fuse has tripped, please reset directly on the uni. See manual for resetting fuse.
EmpirBus NXT
If you control the system with an Raymarine MFD you can reset fuses from the meny ‘tripped circuits’.
Follow the guide found on the ‘support’ page for installing wipers/diodes.
Support
IMPORTANT!!! Caution shall be taken during this process due to a major risk of damaging the mechanical buttons on the panel. Damaged SP12 panels as a result of button removal will NOT be covered by warranty.
The settings of SP12 panel termination shall be decided and done before the buttons are attached. If you are expanding the network please follow the steps below.
-The button numbers follows from left to right and begins with 1 at the top left corner.
-The termination switch is placed under button 8 on the portrait model and under button 5 on the landscape model.
-Remove the button by following the guide for button removal, found on the ‘support’ page. Support
-On the PCB you will find a microswitch with the numbers 1 and 2. These are the two terminators you can set to ON or OFF (activate/deactivate).
With an expanded network above 6 meter one of the above shall be ON and the other termination placed at the other end of the NMEA2000 network. Alternatively you can set them both to OFF and have the two terminators placed separately in the NMEA2000 backbone.
Follow the guide found on the ‘support’ page for EmpirBus Studio.
Support
Follow the guide found on the ‘support’ page for installing RMDS files on the Raymarine MFD.
Support
analog functions | monitor and control analog signals (V, A, Ω) |
configurable input/output | flexible installation, analog or digital |
advanced lighting control | provides full LED brightness control |
smooth on & off | create your desired ambience |
self adapting units | simple service & replacement |
dimming functionality | full flexibility without limitation |
advanced motor control | reversible polarity functionality. |
multiple function channels | saves installation time, money and space! |
automatic override control | security and safety with manual override |
dedicated high current outputs | outputs up to 18A |
control of complex wiper system | interval function, 1 or 2 speed, synchronization, .... |
11 input channels | analog or digital |
20 output channels | 10 A rating |
advanced lighting control | provides full LED brightness control |
analog functions | monitor and control analog signals (V, Ω) |
smooth on & off | create your desired ambience |
self adapting units | simple service & replacement |
dimming functionality | full flexibility without limitation |
advanced motor control | reversible polarity functionality. |
automatic override control | security and safety with manual override |
control of complex wiper system | interval function, 1 or 2 speed, synchronization..... |
optional CAN/RS485/WiFi | connecting 3rd party devices & app control |
EmpirBus is a generically designed system, suitable for different application areas - with almost endless integration possibilities.
Long experience from demanding installations in marine environments proves the durability and robustness.
Vehicle installations shows the flexibility, along with efficiency in use of space and reduced installation time.
Industrial applications for logic capacity and connectivity, all in a very compact unit.
- Wherever there is a need for a robust, flexible, dynamic or quick electrical installation, EmpirBus is at your service -
Copyright © 2018-2023 Garmin Sweden Technologies AB
This site uses cookies – small text files that are placed on your machine to help the site provide a better user experience. In general, cookies are used to retain user preferences, store information and provide anonymised tracking data to third party applications like Google Analytics. As a rule, cookies will make your browsing experience better. However, you may prefer to disable cookies on this site and on others.
The most effective way to do this is to disable cookies in your browser. You can opt-out here if you wish.
empirbus.com uses cookies to collect statistics from our users, to improve the site and provide a better experience for our users.
If you do not accept the use of cookies on our site, you can turn off or restrict cookies through browser settings or by opting out by clicking the button below.
Function: Google Analytics is Google’s analytics tool that helps website owners understand how their site visitors use their site.
Cookies: _ga, _gat, _gid
Domain: empirbus.com
Read more:
Google Analytics privacy policy
Google Analytics developer guide
Function: Sets wether or not the user has accepted or rejected the cookie notice.
Cookies: viewed_cookie_policy
Domain: empirbus.com
If you wish to Opt-out and delete your cookies or block specifik cookies, there are several ways to do so.
The fastest and best way is to do so via your broser settings.
Read more on how to do that here .
You can withdraw your consent at any time. The delete button will reset the cookie for the consent, if given.
You would have to give the consent again to set the cookie value.
Accept here Accept
Delete Cookies