Trigentic logo

Connect 50 24V!!



Connect 50 now available for 24V installations!


#beatyesterday #creativityunbound

Live preview

EmpirBus Logix!

EmpirBus Studio software have finally been put to rest – thank you for all your great efforts over these years!

Welcome, EmpirBus Logix!!
A new era begins!!

#beatyesterday #creativityunbound

Live preview

Products

  • MCU
    • NXT MCU
  • Control
    • WDU
    • EmpirBus SP12
    • EmpirBus SP8
    • Garmin OneHelm
    • Raymarine MFD
  • Configuration
    • EmpirBus LogiX
    • EmpirBus GraphiX
    • Firmware
    • FAQ
    • Support
  • DCM
    • NXT DCM
    • Connect 50
product-02 product-02 product-02

EmpirBus NXT

Empirbus NXT DCM is based on more than 10 years experience in power distribution using Digital Switching.
We have used our longterm experience, together with the feedback from our customers and then added our own innovative ideas.
EmpirBus NXT DCM provides all features and functionality from the EmpirBus CLC system, added with lot of unique and new possibilities.
product-02
Terms of Use & Best Practice Data sheet Manual GSM Reference Manual

EmpirBus NXT MCU

The EmpirBus NXT Master Control Unit is an essential component of a larger NXT installation, providing multiple functions. It is the central processor that drives the system, provides the computing power, intelligence and decision making. In addition there are various interfaces for connection to external devices and a remote control port.

Features

pc interface via usb mini socket connect & configure
integrated gsm module connectivity wherever
ip65 protection durability
automatic override control robustness





product-02
Data sheet Manual

EmpirBus WDU

The EmpirBus Web Display (WDU) unit is a web server unit to distribute customized graphics to any HTML5-supporting device. The WDU allows any EmpirBus system to be controlled and monitored by a user interface fully optimized for its purpose.

Features

interface via usb socket configure
integrated wifi module connectivity
ip65 protection durability
NMEA 2000 simplicity





product-02
Data sheet Manual Dimensions

EmpirBus SP12

EmpirBus SP12 is a 12x2 way digital switch component for the EmpirBus NXT control, monitoring and distribution system. SP12 is used to provide control inputs to the system via the switches and status information back to the user by the individual LED indicators. An integrated audible warning device provides both operator feedback on key press and should an alarm condition arise an audible warning. Fitting the unit is simple it may be fitted to any flat surface. The SP12 is intended to be fitted internally and operates from -20 to +70C.

Features

12 x 2 programmable switches flexibility
portrait and landscape model designed to blend in
led running and alarm indication for each switch for every need
user designed switch legends design your own buttons
backlight with automatic adjustment night time operation
integrated can-bus terminator simplified
integrated buzzer operator feedback and alarm





product-02

SP8 Dimensions

EmpirBus SP8

EmpirBus SP8 is a 8 way digital switch component for the EmpirBus control, monitoring and distribution system. SP8 is used to provide control inputs to the system via the switches and status information back to the user by the individual LED indicators. Available as vertical (portrait) or horizontal (landspace). Fitting the unit is simple using the supplied template and it may be fitted to any flat surface up to 20mm deep. The SP8 may be fitted internally or externally, when fitted externally the SP8 is waterproof from the front, is UV stable and operates from -20 to +70 deg C.

Features

CAN bus switch panel via Connect 50
8 programmable switches flexibility
led, running and alarm indication dynamic (fixed led colors: orange, orange, red)
user designed switches customized symbol or text
backlight night time operation
designed for marine environment durability & robustness IP67
uv stable designed for outdoor mounting

product-02

Garmin OneHelm

Garmin OneHelm connects all of the power and convenience of advanced home automation from your EmpirBus system to the Garmin MFD. It allows you to control onboard electrical and electronic systems like lighting, air-conditioning, navigation lights, wipers, horns, entertainment systems, security systems and much more from your network-connected multifunction display, smartphone or tablet.

EmpirBus is fully integrated with Garmin OneHelm and is the link between the screen and controlling your electrical system.

product-01
product-02
product-03

Raymarine Digital Switching

Digital Switching by Raymarine brings all of the power and convenience of advanced home automation to your boat. Digital Switching allows you to control onboard electrical and electronic systems like lighting, air-conditioning, navigation lights, wipers, horns, entertainment systems, security systems and much more from your network-connected multifunction display, smartphone or tablet.

EmpirBus is fully integrated with Raymarine Multi Functional Displays and is the link between the screen and controlling your electrical system. EmpirBus is Raymarines exclusive integration partner for Digital Switching.

Raymarine Digital Switching





EmpirBus LogiX

EmpirBus LogiX is used to program any EmpirBus product, this software replaces the EmpirBus Studio tool. EmpirBus LogiX is a powerful graphic programming tool that will set all functionality and features of your system.

If you already have an EmpirBus Coassemble account - log in to Coassemble and find all the information needed to start using EmpirBus LogiX!

If you don't have an EmpirBus Coassemble account, use the link below to apply for an account!
Please use this form to apply for an EmpirBus account.
Requirements: Windows 10 or higher & An EmpirBus account.

EmpirBus Studio

EmpirBus Studio is deprecated and will reach end of life in 2023 Q1.
Replacement software is EmpirBus LogiX.


EmpirBus Guides

EmpirBus Video Guides

EmpirBus LogiX Snippets

EmpirBus Studio Snippets

Kvaser Driver for EmpirBus LogiX (Kvaser Leaf Light HS v2)

Kvaser Driver for Windows

EmpirBus GraphiX

EmpirBus GraphiX Editor is used to adapt an EmpirBus configuration to a touchscreen. The software provides features for designing digital switching pages, more or less without limitations.

Please contact [email protected] to get EmpirBus GraphiX for your specific target platform.

EmpirBus Firmware

Firmware for EmpirBus (excl. WDU) are supplied through EmpirBus LogiX software.

WDU v2 Firmware

NOTE! Only for WDU v2 - GPN: 010-02642-00.

Latest WDU v2 firmware is available through Garmin GPSMAP bundle and Garmin ActiveCaptain. For installations that cannot utilize those methods, WDU v2 can be updated through WDU supervisor with this update.

WDU v2 Firmware 3.11 (WDU v2 Supervisor update only!)

WDU v1 Firmware

NOTE! Only for WDU v1 - GPN: 010-02226-00.

WDU v1 Firmware v1.4.4
Firmware install instructions WDU v1

FAQ

Quick and easy access to the most frequently asked questions.
We will continuously add useful information to assist your work with EmpirBus products.


Red indication on COM led

-Is the NMEA2000 connector properly fitted to the unit?
-Do you have power on the NMEA2000 backbone?
-Is the NMEA2000 backbone is properly terminated?

The module display ELH (Error Limp Home-mode)

Unit does not have any connection with the network, check the NMEA2000 network.
-Check network power.
-Check NMEA2000 termination. The network shall have two terminators installed. To be certain you can power OFF the system and measure OHM between pin 4 and 5 (standard Micro C connector). A proper terminated network has 60 Ohm (two 120 Ohm terminator in parallell).

The display on the DCM or MCU switches from ID number and a Code?

Check ‘Code explanation DCM & MCU’ documentation for more information.
Code explanation DCM & MCU

Check that the system doesn’t have two Master Units

A system with only DCM modules only one can be master, the unit that switches between ID number and CUA is programmed as master.
If you have an MCU in the system, that one is naturally master in the system.
A rare case can occur if you have replaced a DCM with another DCM unit that previously has been programmed as master. The unit will stay acting as a master even if re-programmed.
This can be seen this when the units are power-cycled, the unit still acting as master takes longer time to power up. To remove master mode from a unit you need the program it with an empty configuration file.

The power LED is Red

The polarity on the power cables are shifted (plus/minus).

Switch panel SP12/Membrane panel 8BP – led’s are flashing red

This means that the units doesn’t recognize a master
Check that the NMEA2000 network is properly terminated/connected and powered.

Can’t send configuration to the system

If the option is greyed out there is a master unit missing in the configuration file. Update configuration.
Check that all the units have the latest firmware by performing a firmware upgrade.

Can’t upgrade firmware

If the system has firmware that has not been updated for a long time there might be a need for several retries before the firmware upgrade is successful.
If you have an MCU in the system -start upgrading that units first. Select the master unit separately and perform the upgrade.

The MCU flashes ‘bbb’ or DCM channel indicators flashes red from left to right

The units are still in bootloader mode during a cancelled or failed upgrade of firmware.
Try to upgrade the unit again through Empirbus studio.

External multi-switch buttons doesn’t work

-Check connections and that the resistors are attached and OK.
-Check that the correct type of resistors are attached: 68 ohm if its a multi-switch and 120 ohm if it’s a dual fixed multi-switch.
-Check the input channel that the LED turns green when the button in pressed.
Note: only pulse breakers will work with a multi-switch input channel.

Fuse constantly tripping

-If it’s a new config please check that you have the correct fuse setting on the channel.
-The unit attached to the output channel consumes to much power/current.

Cannot find the all system units on the network in Empirbus Studio

-Check that all units have power and COM led flashes green.
-Upgrade MCU to latest firmware, followed by the rest of the units in the system.

How to replace a DCM with paired/stored EnOcean channels

-Access P10 on your MCU: Hold ‘enter’ for approx. 10 sec until P10 appears (a beep sound shall be heard during the whole process). Release and press enter one time.
-Copying is done in the P10 menu of the MCU. Copy function 1 (CF1) copies from DCM to MCU and copy function 2 (CF2) from MCU to DCM. Number 2 is to be used in this case as you’d like to copy from MCU to DCM.
-Verify that the MCU (and/or DCM) doesn’t say ‘EoA’ before copying as this indicates that there is an existing conflict of stored switches and a decision has to be made what set of switches to use.

How to manually set bus ID on a membrane panel 8BP (NXT)

-Press and hold button 7 for about 20 seconds whilst applying power
-Press button 8 three times, now a number will be displayed instead also flashing, this is the base address.
-Use the button 5 and 6 to step down and up the base address.
-When the new base address have been set press and hold button 7 again for about 20 seconds to store.
-The way the base address is displayed on the membrane panel is as follows:
Indication on button 1 is 0 or 1, 0 when off and 1 when lit.
Indication on button 2 is 0 or 2, 0 when off and 2 when lit.
Indication on button 3 is 0 or 4, 0 when off and 4 when lit.
Indication on button 4 is 0 or 8, 0 when off and 8 when lit.
Indication on button 5 is 0 or 16, 0 when off and 16 when lit.
Indication on button 6 is 0 or 32, 0 when off and 32 when lit.
Indication on button 7 is 0 or 64, 0 when off and 64 when lit.
Indication on button 8 is 0 or 128, 0 when off and 128 when lit.
The base address will be the sum of the indicators lit up.

For Example, if Indication on Button 1 + Button 3 => Address is 1+4 = 5.

The system halts/delays and behaves erratic/strange?

-Check that all units have the latest firmware installed. Firmware NXT
-Verify that you have not programmed a channel with functions that it doesn’t support:
Fuse settings, channel support on your unit (example: an input channel has been programmed as an output channel), specific channel support under it’s properties.
-Check that the system doesn’t have two masters.

Red channel indication on DCM

The fuse has tripped, please reset directly on the uni. See manual for resetting fuse.
EmpirBus NXT
If you control the system with an Raymarine MFD you can reset fuses from the meny ‘tripped circuits’.

Install window wipers and placement of diode

Follow the guide found on the ‘support’ page for installing wipers/diodes.
Support

Change termination on an SP12 switch panel

IMPORTANT!!! Caution shall be taken during this process due to a major risk of damaging the mechanical buttons on the panel. Damaged SP12 panels as a result of button removal will NOT be covered by warranty.

The settings of SP12 panel termination shall be decided and done before the buttons are attached. If you are expanding the network please follow the steps below.

-The button numbers follows from left to right and begins with 1 at the top left corner.
-The termination switch is placed under button 8 on the portrait model and under button 5 on the landscape model.
-Remove the button by following the guide for button removal, found on the ‘support’ page. Support
-On the PCB you will find a microswitch with the numbers 1 and 2. These are the two terminators you can set to ON or OFF (activate/deactivate).
With an expanded network above 6 meter one of the above shall be ON and the other termination placed at the other end of the NMEA2000 network. Alternatively you can set them both to OFF and have the two terminators placed separately in the NMEA2000 backbone.

How to install EmpirBus Studio and load configuration files

Follow the guide found on the ‘support’ page for EmpirBus Studio.
Support

How to install the graphic file on the Raymarine MFD (RMDS file)

Follow the guide found on the ‘support’ page for installing RMDS files on the Raymarine MFD.
Support

EmpirBus Support

This support section covers various sections of EmpirBus product management.
Guides to software, installation manuals and contact details to our support.
We will continuously add useful information and documentation to this section to
assist the management of EmpirBus products.

Contact information

E-mail: [email protected]
Phone: +46 522 44 22 22
Monday - Friday, 8am - 12am & 1pm - 5pm (CET/CEST)

8BP

8BP Switch Panel - Discontinued/Spare part sales only
Contact support for more information!

EmpirBus CLC

Link to EmpirBus CLC documentation and software.

EmpirBus CLC



EmpirBus Video Guides Terms of Use & Best Practice Guide EmpirBus Project Start-Up Guide Installation EmpirBus Studio Guide Graphic Export to WDU Installation guide Graphic file Raymarine MFD LightHouse II Installation guide Graphic file Raymarine MFD LightHouse III Code explanation DCM & MCU Window wiper diode configuration Application Specific PGN-65280 SP12 button removal instruction SP12 button legends Molex MX150 Assembly instruction Module dimensions



product-02
Terms of Use & Best Practice Data sheet Manual

EmpirBus NXT DCM

Empirbus NXT DCM is based on more than 10 years experience in power distribution using Digital Switching.
We have used our long term experience, together with the feedback from our customers and then added our own innovative ideas.
EmpirBus NXT DCM provides all features and functionality from the EmpirBus CLC system, added with a lot of unique and new possibilities.

Features

analog functions monitor and control analog signals (V, A, Ω)
configurable input/output flexible installation, analog or digital
advanced lighting control provides full LED brightness control
smooth on & off create your desired ambience
self adapting units simple service & replacement
dimming functionality full flexibility without limitation
advanced motor control reversible polarity functionality.
multiple function channels saves installation time, money and space!
automatic override control security and safety with manual override
dedicated high current outputs outputs up to 18A
control of complex wiper system interval function, 1 or 2 speed, synchronization, ....




product-02
Terms of Use & Best Practice Data sheet Manual

EmpirBus Connect 50

Empirbus Connect 50 is a new version of the NXT DCM designed for smaller or less complex installations. The durability and competence from the NXT DCM has been used to develop a unit that delivers outstanding cost/channel ratio - without leaving important & useful functionality behind!

Features

11 input channels analog or digital
20 output channels 10 A rating
advanced lighting control provides full LED brightness control
analog functions monitor and control analog signals (V, Ω)
smooth on & off create your desired ambience
self adapting units simple service & replacement
dimming functionality full flexibility without limitation
advanced motor control reversible polarity functionality.
automatic override control security and safety with manual override
control of complex wiper system interval function, 1 or 2 speed, synchronization.....
optional CAN/RS485/WiFi connecting 3rd party devices & app control




Installations



customers_1
customers_2
customers_4
customers_6

EmpirBus is a generically designed system, suitable for different application areas - with almost endless integration possibilities.

Long experience from demanding installations in marine environments proves the durability and robustness.
Vehicle installations shows the flexibility, along with efficiency in use of space and reduced installation time.
Industrial applications for logic capacity and connectivity, all in a very compact unit.


- Wherever there is a need for a robust, flexible, dynamic or quick electrical installation, EmpirBus is at your service -

News


2020-04-20 - Updated version of EmpirBus Graphic v2.4

2019-11-01 - Connect 50 24V release

2019-06-30 - Release of EmpirBus Cloud Solutions

2018-12-01 - New product release. HTML5 Web server for EmpirBus (WDU)

2018-03-14 - New company name, Garmin Sweden Technologies AB

2018-02-20 - Garmin® acquires Trigentic

2017-10-01 - New address (same location!!) - Spikvägen 1, 45175 Uddevalla Sweden

2017-05-01 - Updated version of EmpirBus Graphic v2.1

2016-11-01 - New CAN-bus switch panel introduced, SP-8

2016-03-01 - EmpirBus new DC-module, Connect 50, released!

2015-12-17 - Updated version of EmpirBus Studio released including copy/paste

2015-11-17 - RSS feed to follow new releases of firmware available (Products/Configuration/Firmware)

2015-11-17 - A new website is launched.

2014-12-08 - Trigentic moves to new location (Bultvägen 1, UDDEVALLA, Sweden)

About & Contact

About us

Garmin Sweden Technologies AB is a company who delivers innovative and intelligent products, solutions and services in the areas of embedded systems, power supply and power distribution. Our products are distributed by our network of selected partners. Find your nearest distributing partner in the list. If you have an interest in becoming an EmpirBus partner, please contact us.

Garmin Sweden Technologies AB

Spikvägen 1
451 75 UDDEVALLA
SWEDEN

Map & Driving directions

Support Phone: +46 522-44 22 22
[email protected]

Global distributors

Garmin

Raymarine

Distributors & Resellers

Australia

Safiery Ptd Ltd
Barrenjoey Marine Electrics
Outback Marine

Croatia

Locomarine d.o.o

Denmark

KEM-Montering ApS
Lyngaa-Marine ApS

Finland

Kewatec Aluboat

France

Kent Marine Equipment

Germany

Yachtelektronik Höppli

Holland

Yacht Control

Norway

Isbåter

Spain

Nautic Supply Iberia

Switzerland/Italy

Be Positive
Yachtech AG

Sweden

Odelco AB

Turkey

ECR Marine

UK

Atlantis Marine Power

Copyright © 2018-2023 Garmin Sweden Technologies AB

Terms of Use

Produced by YMER IT

Empowering Electrical Systems

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish.Accept Reject Read More
Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
SAVE & ACCEPT

Cookies

This site uses cookies – small text files that are placed on your machine to help the site provide a better user experience. In general, cookies are used to retain user preferences, store information and provide anonymised tracking data to third party applications like Google Analytics. As a rule, cookies will make your browsing experience better. However, you may prefer to disable cookies on this site and on others.
The most effective way to do this is to disable cookies in your browser. You can opt-out here if you wish.

empirbus.com uses cookies to collect statistics from our users, to improve the site and provide a better experience for our users.

If you do not accept the use of cookies on our site, you can turn off or restrict cookies through browser settings or by opting out by clicking the button below.

Cookies we use

Google Analytics

Function: Google Analytics is Google’s analytics tool that helps website owners understand how their site visitors use their site.
Cookies: _ga, _gat, _gid
Domain: empirbus.com

Read more:
Google Analytics privacy policy
Google Analytics developer guide

Viewed Cookie Policy

Function: Sets wether or not the user has accepted or rejected the cookie notice.
Cookies: viewed_cookie_policy
Domain: empirbus.com

Opt-out

If you wish to Opt-out and delete your cookies or block specifik cookies, there are several ways to do so.
The fastest and best way is to do so via your broser settings.
Read more on how to do that here .

Accept or reject cookie consent.

You can withdraw your consent at any time. The delete button will reset the cookie for the consent, if given.
You would have to give the consent again to set the cookie value.

Accept here Accept
Delete Cookies